Specifications for
Sterilight Ultraviolet Disinfection System
Point Of Use - 12.0 / 15.0 gpm

The Sterilight DS12Q
water disinfection system carries a seven year warranty on the stainless
steel reactor chamber, a one year warranty on UV lamps and monitor probes,
and a five year pro rated warranty on all other components.
Note: on the chart below
mJ/cm2 means millijewels per cubic centimeter
SPECIFICATIONS
|
|
|
F
L
O
W
|
U.S. Public Health
16 mJ/cm2
|
90
L/min (24 gpm) max |
|
R-Can Standard
30 mJ/cm2
|
49
L/min (13 gpm) max |
|
NSF / EPA
40 mJ/cm2
|
34.1
L/min (9 gpm) max |
|
Length
|
94 cm
(37")
|
|
Width
|
17.8 cm
(7")
|
|
Height
|
20 cm
(8")
|
|
Cell
Diameter
|
9 cm
(3.5")
|
|
Shipping
Weight
|
10.5 kg (23
lbs.)
|
|
Voltage
|
100-130V./50-60Hz
or
200-250V./50- 60Hz.
|
|
Power
Consumption
|
42
|
|
Total Lamp
Watts
|
39
|
|
Maximum
Operating Pressure
|
8.62 bar
(125 psi)
|
|
Ambient
Temperature
|
2 - 40°C
(36 - 104°F)
|
|
Quartz
Sleeve
|
Yes
|
|
Inlet/Outlet
Port Size
|
1"
MNPT / 3/4" FNPT "combo"
|
|
Visual Lamp
Failure
System
|
Yes
|
|
Audible
Lamp Failure
System
|
Yes
|
|
254 nm UV
Sensor
|
No
|
|
Solenoid
Output
|
No
|
|
Infrared
Output
(Remote Alarm)
|
No
|
|
Reactor
Chamber
Material
|
304
Stainless Steel (316L
Optional)
|
Replacement
Parts
- S36RL, UV lamp
- OR212, o-ring
- BAICE-3F,
100-250V./50-60Hz. audible electronic ballast
- RN-001, aluminum
gland nut
Troubleshooting Guide (in .pdf format)
|